IN-9008 Full HD Manual
Lense Adjustment
Objektivjustage
Objektiv scharfstellen IN-9008FullHD. Auf Youtube ansehen
The IN-9008 Full HD standard lense has a depth of field (also focus range) that is adjusted to a distance of approx. 1 - 8m. In case your area of interest is out of focus, you will have to adjust the lense accordingly.
I. Slide to top cover towards the front to take it off and loosen the four screws at the front cover of the camera.
II. Carefully remove the front cover from the main casing and put it aside.
III. Open the WebUI and check the live video. Turn the lense, until your area of interest is in focus. If you turn the lense clockwise, the plane of focus moves away from the camera image sensor.
IV. If you turn the lense counter clockwise, the plane of focus moves towards the image sensor.
V. After you adjust the focal point, carefully reinstall the front cover to the casing and tighten the screws again. Also slide back the top cover.