The System Menu :: PTZ Tour




param.cgi?cmd=setptztour

FunctionSet a Pan&Tilt Tour
Authorityadmin
Parametervar tour_enable [0, 1] - If Active the Alarmpreset Function has to be Deactivated!
var tour_times: [1-50] Tour Repetitions
var tour_index: Positions 0-7 divided by Semicolons
var tour_interval: Resting Time on Position in Seconds [5-43200] divided by Semicolons
RemarksIf Active, the Alarmpreset Function has to be deactivated!
ExampleGET: http://admin:instar@192.168.2.168/cgi-bin/hi3510/param.cgi?cmd=setptztour&-tour_enable=1&-tour_index=0;1;2;3;4;5;6;7&-tour_interval=5;5;5;5;5;5;5;5&-tour_times=50&cmd=setmdalarm&-aname=preset&-switch=off


param.cgi?cmd=ptzctrl

FunctionStart Pan&Tilt Tour
Authorityadmin
Parametervar step [0, 1] - set to 0 for tour function!
var act [tour, hscan, vscan, stop] - activate PTZ Tour, horizontal or vertical Scan or Stop Function
RemarksIf Active, the Alarmpreset Function has to be deactivated!
ExampleGET: http://admin:instar@192.168.2.168/cgi-bin/hi3510/param.cgi?cmd=ptzctrl&-step=0&-act=tour
GET: http://admin:instar@192.168.2.168/cgi-bin/hi3510/param.cgi?cmd=ptzctrl&-step=0&-act=stop