Downloads

InstarVision for Windows Desktop Downloads

Desktopsoftware für Ihre Netzwerkkameras

Die Software InstarVision hilft Ihnen dabei Ihre Kameras besser zu verwalten. Mit diesem können Sie je nach Lizenztyp bis zu 64(!) Kameras einbinden und diese gleichzeitig einsehen. Über die Software können Sie zudem Aufnahmen in verschiedenen Dateiformaten speichern und eine erweiterte Bewegungserkennung nutzen.

Versionshistorie mit Features

Version 3.0
  • Download [SHA265: 7f809350e779a99c5afa5c35b202af2c33723fee99d7cabca2be23674cc1197d] *
  • User Manual
Changes
Unterstützung für 2K+ WQHD h.265 Kameramodelle hinzugefügt.
Version 2.7
  • Download [SHA265: 26e6edb875a67dd69fcc94bd4b30154c39a562a08ec31e5d437e3f2d5374999f] *
  • User Manual
Changes
Problem with logbook solved that it was not displayed
Fixed a problem that caused a continuous alarm when a connection was lost
In case of continuous recording, alarm recording stops the continuous recording video, creates a new file for alarm, and after the alarm, creates and records a new continuous recording file. Previously there was a bug that an alarm video was named, but the length of the recording was the same as the duration recording
Version 2.6
  • Download [SHA265: 563f8e3db342672d45c88b14262f419b4ee072c0b0b216436a304565cb522f07] *
  • User Manual
Changes
Bugfixes and new Features
Version 2.5r355
  • Download [SHA265: 091fafc2bedec78ad8922bc980d301fe1fbb1aa5f015d002a4253119783e2221] *
  • User Manual
Changes
Folder structure adjustable by date/channel or channel/date
Recording files get new file names with A (alarm), P (scheduled recording), T (test) and N (manual recording) just as local recordings on your camera`s SD card
Camera name can be added as a prefix to the recording file to keep recordings sorted
FTP upload of videos is now possible (images and/or videos can be selected separately)
Camera name as folder instead of CH01, CH02...
Solved problem with Multi-Monitor function
Triggering of an external script or program now also possible without having to start a recording
User and password can now be up to 63 characters long
Many more minor bugfixes
Version 2.4
  • Download [SHA265: 544c280cf361375d2d36d72f18dc22441da9d80f4e58638157506a4a1b34900f] *
  • User Manual
Changes
A new layout has been added, showing 2 channels separated horizontally.
Maps now adapt to the window size.
The overview of the result of a camera search has been improved. The results are now sorted and better positionized.
A map can now also be deleted with the minus button.
A rotation button has been added for each channel, allowing the video image to be rotated 90 degrees.
If a camera is unreachable, an error message will now be displayed in the middle of the video, indicating why the connection can not be established.
If the "program is locked" (click on lock icon) and no software login was previously activated or you are logged in with a user with the name "admin", then the standard login data ("admin", "instar") will be pre-filled, so that you can immediately unlock the software by clicking on "Ok", if you accidentally clicked on it.
The configuration of a schedule has been completely redesigned. So you can configure these now, like the schedules of an instar camera. For the "Continuous recording", the "Alarm recording" and the "Photoseries" there is now a table in which for each day of the week an arbitrary time range can be selected by 15 min sections. It is now easy to determine at a glance when recordings are taken and when not. Whether recordings are made for the currently selected channel can be set with the check mark "Activate recording".
Added a validation for port inputs.
The sensitivity slider has been improved so that the entire range can now be configured fine grained. Please note that although the value is adjusted during a software update to this version, it can not be 100% converted. The sensitivity and the upper and lower limits may need to be adjusted manually.
In a photo series, the FTP upload worked so far only if it was also locally saved. This coupling has now been lifted.
Added the new camera models "IN-9020 Full HD" and "IN-8003 Full HD" to the list of selectable cameras. In addition, the entry for the models "IN-8015 Full HD" and "IN-9008 Full HD" was split into two separate entries.
If a video channel whose camera has no PTZ function is selected, "PTZ Camera" will now "No PTZ available." displayed.
Under "Camera PTZ" buttons for manual focusing have been added for the "IN-9020 Full HD". Although the focus is automatically readjusted after zooming in or out, it can now be readjusted using the "+" and "-" buttons as in the camera web interface. In addition, two new menu items for "in-focus" and "out-focus" will now also be added to the global "Pan & Tilt" menu (Citizen icon) if "IN-9020 Full HD" is selected in the video display.
The CPU load with activated alarm detection was significantly reduced per channel, so that it only needs a few percent more compared to the load without alarm detection.
The CPU load when previewing the alarm detection has been reduced.
The preview of the alarm detection has been improved so that now, with overlapping areas, the motion pixels are displayed in the color of the area at which a motion was detected at last. The order is R1, R2, R3 and then R4. This allows you to see which parts in the overlap have been detected by which setting. Previously, the motion pixels were always displayed in the color of the first area, even if the movement was detected by the setting of another overlapping area.
InstarPlayer is now also available in German. Depending on which language is set in the InstarVision this changes between German and English.
A security question has been added, indicating that exported configurations can only be reimported with the same version.
Fixed a display problem after changing a layout through the burger menu.
Added the possibility to change the user name.
Added Focus and Zoom functionality for Instar P2P (only possible with focus and zoom camera such as the IN-9020 FullHD).
The ip address is now protected against incorrect entry.
An error message will be displayed if the InstarVision can not be registered.
For a better overview the dialog for the camera selection has been revised, so that depending on the camera type only the relevant input fields are displayed.
A new menu item has been added to the camera list to start or stop all channels with one click.
After a channel has been maximized, the maximize button will now be displayed as a minimize button.
The name of the camera is now transferred when selecting a camera search result.
The expired certificate in the signature of the software has been renewed.
Changes
The audio of a continuous recording was not stored properly for some time, so that after a few recordings the audio sounds only very distorted. This bug has been fixed now.
Already fixed but no longer working after the changes to the 2.3 beta. The InstarPlayer does not start by default with the selected recording path if it was started from the InstarVision.
The robber icon, which appears above the video display of a channel and allows the InstarVision`s motion detection to be turned on and off, did not work. This bug has now been fixed.
Fixed a bug where if a wrong password was entered when logging on a user, it could happen that the resulting error message was displayed twice in succession.
Under the alarm recording settings, the text "Starte Programm bei Alarm" has not been fully displayed.
The IR LED status of a channel, which can be displayed above the video display and switched with a click on the camera, does not work. This bug has now been fixed.
It has been possible for a logged in user who did not have the right to watch a video channel to watch it through stopping and starting. This is no longer possible.
The user interface was not updated after changing the logged in user or only after a restart of the software.
Previously, it was possible for a user who was not an administrator but had the system right to disable the software login. After deactivation and restart it could then change all user rights. This is no longer possible because the software login setting now is greyed out in this case.
The identifiers of the buttons under "User" did not have a German translations.
The default user did not appear under "About InstarVision."
Fixed a bug that could cause cameras from other manufacturers to not be able to integrate them via the JPEG mode.
It has been possible to delete the last remaining administrator user. This is now prevented by a safty check dialog.
Fixed a bug that caused a crash in a P2P connection if switching the IR LEDs.
The camera focus was not synchronized with the camera list.
After deleting a channel, the view was not changed to the last remaining channel.
The camera search did not always provide all the results.
An error has been fixed that certain special characters were not displayed correctly in the result list of a camera search.
Version 2.3
  • Download [SHA265: 8c66fe1dfa8bc808940383bffc8ce7a870c9717f5a686abbbd80cb6c98ad9471] *
  • User Manual
Changes
All executable files are now certified so they are no longer considered potentially dangerous under strict antivirus software settings.
The version is now also shown in the file details.
Under "About InstarVision" now the revision number is displayed and displayed whether it is a BETA version.
The revision number is now stored in the Windows registry and the configuration file.
The location where the configuration and log files are stored has been changed. As a result, logged-in Windows users can now use different InstarVision configurations (more details under "Fixed bugs").
The configuration file converter has been extended so that it is now possible to update directly from an older 2.x version. For example, an InstarVision 2.0 version can now be updated directly to this 2.3 version without going through the steps from 2.0 to 2.1, 2.1 to 2.2 and 2.2 to 2.3.
Changes
The software sometimes crashed after an unavailable channel was restored.
Removed the wrong "IN-4010" entry at the camera model selection box and added the entry "IN-9008 Full HD PoE"
Fixed PTZ issues for camera models "IN-4010", "IN-4010 V2" and "IN-4011". In addition, the control of the "IN-8015 Full HD" was changed from step-by-step control to control with stop command, resulting in a smoother movement when controlling with the directional pad.
An update kept the old Start Menu and Desktop Shortcuts entries. These old entries now will be deleted during an update.
Fixed a bug in the configuration file converter that could cause the backup file to be named incorrectly.
In case of missing write permissions to the installation directory, despite of a valid license codes, it was still queried again and again and so the InstarVision could not be started or used. This can no longer happen now because the location where the configuration and log file are saved has been changed to a user-specific folder "C:\Users\<username>\AppData\Roaming\InstarVision“ on which write access exists by default. Running the software as an administrator during a standard installation under "Program Files (x86)" is therefore no longer necessary.
Version 2.2
  • Download [SHA265: 621fc72609fc190fb6b27a69b786bdbee38d73a66b6afd0ace9d1c6e27f28cd7] *
  • User Manual
Changes
Integration of the Instar Full HD camera models IN-8015 Full HD and IN-9008 Full HD
Integration of the in-house P2P solution
Revision of motion detection
Update process for new versions (through the installer)
Added link to user manual
Changes
Corrected spelling errors and renamed texts to increase understanding.
The buttons for registration are now always displayed under "Extended-> License" (not only for license changes)
The "Email Registration" and "Generate ID" buttons were reversed in their function.
Problems with changing and displaying Instar VGA and HD picture settings when switching channels have been fixed.
Problems with setting changes when using P2P cameras have been fixed.
The crash when recording when the recording path contains umlauts or other special characters has been fixed.
If unsupported channel bindings are selected, e.g. P2P no longer crashes the software when HTML5 is selected in the web client.
Version 2.1 BETA
  • Download [SHA265: 3c7f7738cbcd0303c15a340f88895d5495689af8215c968343eb62431ca3fa33] *
  • User Manual
Changes
Revised motion detection
FTPS support for alarm uploads
Integration of the new 720p camera models
Move the video channels by Drag&Drop
Version 2.0
Changes
Restrict the motion detection area
Access to InstarVision over the Internet
Streaming in many different formats
User management with defined sharing of cameras
Version 1.3
Changes
Definition of 64 areas for motion detection
Motion detection for each channel
Recording detection before movement
Recording in different recording formats
Version 1.2
Changes
New user interface
User management with permission for each camera
Recording BEFORE moving with an alarm
upports up to 32 network cameras
Obsolescent Versions