The Areas Overlay
param.cgi?cmd=setmdattr

FunctionSet the Motion Detection Areas
Authorityadmin
Parametername: Alarm Area [1-4]
enable: [0, 1] De/Activate Area
s: Sensitivity [0-100]%
x: X-Coordinate Origin [0-(1280-w)]
y: Y-Coordinate Origin [0-(720-h)]
w: Area Width [1-1280] Pixel
h: Area Height [1-720] Pixel
ReturnSuccess, Error
RemarkSee Param.cgi?cmd=getmdattr and Param.cgi?cmd=setmdattr
Examplehttp://admin:instar@192.168.178.88/cgi-bin/hi3510/param.cgi?cmd=getmdattr
http://admin:instar@192.168.178.88/param.cgi?cmd=setmdattr&-name=1&-enable=1&-s=100&-x=0&-y=0&-w=1280&-h=720&cmd=setmdattr&-name=2&-enable=0&-s=0&-x=1120&-y=0&-w=160&-h=160&cmd=setmdattr&-name=3&-enable=0&-s=0&-x=0&-y=560&-w=160&-h=160&cmd=setmdattr&-name=4&-enable=0&-s=0&-x=1120&-y=560&-w=160&-h=160
The Web User Interface

The Web User Interface

Find a detailed description of the web user interface of your 1080p Series, 720p Series or VGA Series Cameras.